| 14 | |
| 15 | == Status uitlezen via de shell == |
| 16 | |
| 17 | Dit kan op de volgende manier: |
| 18 | {{{ |
| 19 | [Syn-3] root@kantoor2.server.nl ~# smartctl -a /dev/sda |
| 20 | smartctl version 5.37 [i586-pc-linux-gnu] Copyright (C) 2002-6 Bruce Allen |
| 21 | Home page is http://smartmontools.sourceforge.net/ |
| 22 | |
| 23 | === START OF INFORMATION SECTION === |
| 24 | Device Model: WDC WD1600AAJB-00J3A0 |
| 25 | Serial Number: WD-WCAV30438479 |
| 26 | Firmware Version: 01.03E01 |
| 27 | User Capacity: 160,041,885,696 bytes |
| 28 | Device is: Not in smartctl database [for details use: -P showall] |
| 29 | ATA Version is: 8 |
| 30 | ATA Standard is: Exact ATA specification draft version not indicated |
| 31 | Local Time is: Mon Apr 6 17:26:37 2009 CEST |
| 32 | SMART support is: Available - device has SMART capability. |
| 33 | SMART support is: Enabled |
| 34 | |
| 35 | === START OF READ SMART DATA SECTION === |
| 36 | SMART overall-health self-assessment test result: PASSED |
| 37 | |
| 38 | General SMART Values: |
| 39 | Offline data collection status: (0x84) Offline data collection activity |
| 40 | was suspended by an interrupting command from host. |
| 41 | Auto Offline Data Collection: Enabled. |
| 42 | Self-test execution status: ( 0) The previous self-test routine completed |
| 43 | without error or no self-test has ever |
| 44 | been run. |
| 45 | Total time to complete Offline |
| 46 | data collection: (2880) seconds. |
| 47 | Offline data collection |
| 48 | capabilities: (0x7b) SMART execute Offline immediate. |
| 49 | Auto Offline data collection on/off support. |
| 50 | Suspend Offline collection upon new |
| 51 | command. |
| 52 | Offline surface scan supported. |
| 53 | Self-test supported. |
| 54 | Conveyance Self-test supported. |
| 55 | Selective Self-test supported. |
| 56 | SMART capabilities: (0x0003) Saves SMART data before entering |
| 57 | power-saving mode. |
| 58 | Supports SMART auto save timer. |
| 59 | Error logging capability: (0x01) Error logging supported. |
| 60 | General Purpose Logging supported. |
| 61 | Short self-test routine |
| 62 | recommended polling time: ( 2) minutes. |
| 63 | Extended self-test routine |
| 64 | recommended polling time: ( 38) minutes. |
| 65 | Conveyance self-test routine |
| 66 | recommended polling time: ( 5) minutes. |
| 67 | |
| 68 | SMART Attributes Data Structure revision number: 16 |
| 69 | Vendor Specific SMART Attributes with Thresholds: |
| 70 | ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE |
| 71 | 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 |
| 72 | 3 Spin_Up_Time 0x0027 147 147 021 Pre-fail Always - 3633 |
| 73 | 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 8 |
| 74 | 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 |
| 75 | 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 |
| 76 | 9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 1009 |
| 77 | 10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0 |
| 78 | 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0 |
| 79 | 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 6 |
| 80 | 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 4 |
| 81 | 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 8 |
| 82 | 194 Temperature_Celsius 0x0022 101 094 000 Old_age Always - 42 |
| 83 | 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 |
| 84 | 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 |
| 85 | 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0 |
| 86 | 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 |
| 87 | 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0 |
| 88 | |
| 89 | SMART Error Log Version: 1 |
| 90 | No Errors Logged |
| 91 | |
| 92 | SMART Self-test log structure revision number 1 |
| 93 | Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error |
| 94 | # 1 Extended offline Completed without error 00% 658 - |
| 95 | # 2 Extended offline Completed without error 00% 634 - |
| 96 | # 3 Extended offline Completed without error 00% 610 - |
| 97 | # 4 Extended offline Completed without error 00% 586 - |
| 98 | # 5 Extended offline Completed without error 00% 562 - |
| 99 | # 6 Extended offline Completed without error 00% 538 - |
| 100 | # 7 Extended offline Completed without error 00% 514 - |
| 101 | # 8 Extended offline Completed without error 00% 490 - |
| 102 | # 9 Extended offline Completed without error 00% 467 - |
| 103 | #10 Extended offline Completed without error 00% 443 - |
| 104 | #11 Extended offline Completed without error 00% 419 - |
| 105 | #12 Extended offline Completed without error 00% 395 - |
| 106 | #13 Extended offline Completed without error 00% 371 - |
| 107 | #14 Extended offline Completed without error 00% 347 - |
| 108 | #15 Extended offline Completed without error 00% 323 - |
| 109 | #16 Extended offline Completed without error 00% 299 - |
| 110 | #17 Extended offline Completed without error 00% 275 - |
| 111 | #18 Extended offline Completed without error 00% 251 - |
| 112 | #19 Extended offline Completed without error 00% 227 - |
| 113 | #20 Extended offline Completed without error 00% 203 - |
| 114 | #21 Extended offline Completed without error 00% 179 - |
| 115 | |
| 116 | SMART Selective self-test log data structure revision number 1 |
| 117 | SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS |
| 118 | 1 0 0 Not_testing |
| 119 | 2 0 0 Not_testing |
| 120 | 3 0 0 Not_testing |
| 121 | 4 0 0 Not_testing |
| 122 | 5 0 0 Not_testing |
| 123 | Selective self-test flags (0x0): |
| 124 | After scanning selected spans, do NOT read-scan remainder of disk. |
| 125 | If Selective self-test is pending on power-up, resume after 0 minute delay. |
| 126 | |
| 127 | |
| 128 | }}} |
| 129 | |
| 130 | Zo kunt u ook zien of er nog een selftest gaande is en wat er precies aan de hand is. |